Perkins 1206A-E70TTAG3 Twin-Turbo Diesel Engine

Next-generation 7.01L series-turbocharged Common Rail diesel engine rated at 202.0–223.0 kW (1500 RPM) for 250 kVA generator sets.

  • Standby Power (ESP)223.0 kW (299.0 hp)
  • Prime Power (PRP)202.0 kW (270.9 hp)
  • Displacement7.01 L

Verified Prior to Quotation. Fitment and configuration are cross-checked against your equipment serial number.

Technical Overview

About Perkins 1206A-E70TTAG3 Twin-Turbo Diesel Engine

The Perkins 1206A-E70TTAG3 from the 1200 Series utilizes two-stage series turbocharging (Twin Turbo), a high-pressure Common Rail fuel system, and full authority electronic control to achieve 8-liter class power density from a compact 7.0-liter six-cylinder footprint.

Perkins is pleased to announce the natural expansion of the 1200 Series to include a new addition to the ElectropaK range.

The whole engine has been built around the demands of our customers and as such offers a great package with a simple integration design.

Perkins have developed a reputation for designing and building reliable and durable engines suitable for the most demanding applications.

Dependable power

World-class manufacturing capability and processes coupled with proven core engine designs assure reliability, quiet operation, and many hours of productive life.

Series turbocharging with smart wastegate available on all ratings.

A high power density product that combine dependable power and high efficiency at the same time. Driving lower cost of ownership along with better performance.

Industry leading flexibility

Perkins is proud to offer unrivalled flexibility and our EP engines are no exception. A tropical radiator is supplied as standard.

Lifetime of low cost

Fuel consumption optimized prime power and continuous running applications. No additional fluids or additives are required which lowers operating costs

Hydraulic tappets, multi-vee belts, service free aftertreatment and 500 hour oil change intervals also keep your maintenance costs as low as possible.

Supply Assurance

MSDD Engine Standards

01
Genuine Quality & Fitment Check

We verify fitment by engine nameplate and serial number, with pre-shipment photos of original packaging.

02
Direct Export Logistics

Direct dispatch from our Chongqing hub for industrial fleets, power plants, and service centers.

03
Locked Commercial Terms

Unit price, completeness, export crating, and lead time are confirmed before invoicing.

Technical Data

Specifications

Reference parameters for engineering selection; exact arrangement details are confirmed prior to shipment. Manufacturer names and part numbers are used for identification reference only.

Additional Parameters
Model / Code1206A-E70TTAG3
BrandPerkins
Bore × Stroke105.0 × 135.0 mm
AspirationSeries Twin-Turbocharged & Aftercooled (TTAG)
Fuel SystemHigh-Pressure Common Rail (Electronic)
Fuel Consumption (100% Prime)52.1 L/h
Lube Oil / Coolant Capacity16.5 L / 25.0 L
Overall Dimensions (L × W × H)1964 × 956 × 1243 mm
Dry Weight820 kg
Compatible ModelsFG Wilson P250-2, 250–275 kVA Generator Sets, Industrial Standby Power Plants

Engineering Advantage

Why Specify Perkins 1206A-E70TTAG3 Twin-Turbo Diesel Engine

01

Power rating and duty cycle are matched to your exact application — from continuous prime load to heavy intermittent duty.

02

Equipment compatibility is verified before quotation: flywheel housing, cooling package, and PTO configuration are aligned with your machinery.

03

Site conditions are factored into selection: ambient temperature, altitude derating, and fuel quality requirements.

04

Scope of supply is locked in the commercial quotation and verified prior to dispatch.

05

Engine serial number, factory test records, and export documentation are provided for full traceability.

Applications

Typical Applications

Engineered for demanding industrial duty cycles. Application rating, mounting arrangement, and cooling configuration are confirmed prior to shipment.

Logistics & Packaging

Delivery Terms

Quantity, export packaging, gross weight, and dispatch lead time are confirmed in your formal quotation.

Packaging
Export-grade protective packaging
Unit Weight
820 kg
Minimum Order
1 unit / per enquiry
Lead Time
Confirmed prior to order

Before You Order

Frequently Asked Questions

What technical details are required for sizing and quotation?

Please specify your required power output (kW/kVA), operating duty (Prime or Standby), ambient conditions (altitude and temperature), voltage/frequency, and destination country.

Can the configuration and scope of supply be customized?

Yes. Cooling packages, flywheel housings, control panels, canopies, and ATS switchgear are confirmed to match your application prior to quotation.

Request a Quotation

Submit Your Enquiry

Request Configuration & Price — share your requirements below and our engineers will verify fitment and stock availability.

By submitting this form, you agree to our Privacy Policy and Terms of Service. Your technical data and nameplate photos are used strictly for quotation and fitment verification.

If online submission is unavailable, a pre-filled email will open automatically.

↑