Generator Sets•Perkins

Perkins 4008TAG ElectropaK Power Generation Engine

The 8 cylinder Perkins 4008 range gives you the versatility you need in today’s power generation market. The range’s diesel ElectropaK engines/Electro Units deliver 849-1022 kVA and are

  • 50 Hz Standby Power1002 – 1138 kVA
  • 60 Hz Standby Power780 – 878 kWe
  • 50 Hz Prime Power911 – 1035 kVA

Verified Prior to Quotation. Fitment and configuration are cross-checked against your equipment serial number.

Technical Overview

About Perkins 4008TAG ElectropaK Power Generation Engine

The 8 cylinder Perkins 4008 range gives you the versatility you need in today’s power generation market. The range’s diesel ElectropaK engines/Electro Units deliver 849-1022 kVA and are supplied with or without radiator and air cleaner.

This engine has proven reliability in prime and standby installations in all of the key sectors, such as manufacturing facilities, hospitals, and data centres. The 4008 engines have exceptional power-to-weight ratios and compact designs, making them simple to transport and install.

Air inlet system

  • Mounted air filters and turbochargers

Cooling system

  • Crankshaft pulley for fan drive
  • Gear driven circulating pump
  • Twin thermostats

Electrical equipment

  • 24 volt combined high coolant temperature/low oil pressure switch
  • 24 volt Electronic Shut Off Solenoid (ESOS) (energised to run)
  • 24 volt starter motor and 24 volt/40 amp alternator with integral regulator and DC output
  • Overspeed switch and magnetic pickup
  • Turbine inlet temperature shutdown switch

Flywheels and flywheel housing

  • Flywheel to SAE J620 size 18
  • SAE 0 flywheel housing

Fuel system

  • Full flow spin-on fuel oil filters
  • Electronic governor to ISO 3046 Part 4 class A1
  • Unit fuel injectors with lift pump and hand stop control

Oil system

  • Engine jacket water/lubricating oil temperature stabiliser
  • Full flow spin-on oil filters
  • Wet sump with filler and dipstick
 

Optional Equipment

Options for your 4008 range diesel engines include:

• Tropical radiator, including water pipes, clips and hoses, fan, fan guards and bolts

• Twin heavy-duty air cleaners – paper element with pre-cleaner

• Changeover lubrication oil filter

• Changeover fuel oil filter

• Immersion heater with thermostat

• Air starters

• Instrument panel

Reliable Power

The 4008 range engines provide 884-1250 kVA generator output.

The 8 cylinder option in the 4000 Series, the 4008 range engines can be supplied with cooling systems for either tropical or temperate environments to meet your needs, whatever your location.

Economical and durable, the engines give you excellent power-to-weight ratios, outstanding load acceptance and improved gas emissions.

Supply Assurance

MSDD Engine Standards

01
Genuine Quality & Fitment Check

We verify fitment by engine nameplate and serial number, with pre-shipment photos of original packaging.

02
Direct Export Logistics

Direct dispatch from our Chongqing hub for industrial fleets, power plants, and service centers.

03
Locked Commercial Terms

Unit price, completeness, export crating, and lead time are confirmed before invoicing.

Technical Data

Specifications

Reference parameters for engineering selection; exact arrangement details are confirmed prior to shipment. Manufacturer names and part numbers are used for identification reference only.

Additional Parameters
Model / Code4008-TAG
BrandPerkins
Minimum Rating720 kVA/644Kw
Maximum Rating1125 kVA/997 Kw
50 Hz Prime Power911-1035 kVA
50 Hz Standby Power1002-1138 kVA
60 Hz Prime Power707-796 kWe
60 Hz Standby Power780-878 kWe
Rated Speed1500/1800 rpm
Emissions StandardFuel Optimised

Engineering Advantage

Why Specify Perkins 4008TAG ElectropaK Power Generation Engine

01

Prime (PRP) and Standby (ESP) ratings are sized to your actual load profile and motor starting currents.

02

Electrical parameters are confirmed before quotation: voltage, frequency, controller model, and paralleling or ATS gear.

03

Enclosure format is matched to your site: open skid, soundproof canopy, or containerized package with climate protection.

04

Site altitude, ambient temperature derating, and acoustic limits are engineered into the configuration.

05

Lead time, export crating, and international shipping terms (FOB, CIF, DAP) are fixed prior to order confirmation.

Applications

Typical Applications

Designed for reliable prime and standby power across industrial facilities and critical infrastructure. Enclosure and switchgear are configured to your site.

Logistics & Packaging

Delivery Terms

Quantity, export packaging, gross weight, and dispatch lead time are confirmed in your formal quotation.

Packaging
Export-grade protective packaging
Unit Weight
Confirmed per configuration
Minimum Order
1 unit / per enquiry
Lead Time
Confirmed prior to order

Before You Order

Frequently Asked Questions

What technical details are required for sizing and quotation?

Please specify your required power output (kW/kVA), operating duty (Prime or Standby), ambient conditions (altitude and temperature), voltage/frequency, and destination country.

Can the configuration and scope of supply be customized?

Yes. Cooling packages, flywheel housings, control panels, canopies, and ATS switchgear are confirmed to match your application prior to quotation.

Request a Quotation

Submit Your Enquiry

Request Technical & Commercial Quote — share your requirements below and our engineers will verify fitment and stock availability.

By submitting this form, you agree to our Privacy Policy and Terms of Service. Your technical data and nameplate photos are used strictly for quotation and fitment verification.

If online submission is unavailable, a pre-filled email will open automatically.

↑