Generator Sets•Perkins

Perkins 2206C-E13TAG ElectropaK Power Generation Engine

Perkins 2206C-E13TAG, part of our 2000 Series, the 6 cylinder Perkins 2200 range diesel engine is ideal for your power generation requirements from 350-500 kVA, whether prime or standby

  • 50 Hz Standby Power400 – 450 kVA
  • 60 Hz Standby Power320 kVA
  • 50 Hz Prime Power350 – 400 kVA

Verified Prior to Quotation. Fitment and configuration are cross-checked against your equipment serial number.

Technical Overview

About Perkins 2206C-E13TAG ElectropaK Power Generation Engine

Perkins 2206C-E13TAG, part of our 2000 Series, the 6 cylinder Perkins 2200 range diesel engine is ideal for your power generation requirements from 350-500 kVA, whether prime or standby power. Among the features and benefits of the 2000 Series are flexible packaging to cater for the space you have available, mechanically operated unit fuel injectors, electronic control and carefully matched turbocharging. You’ll find our 2200 range gives the performance and economy you need.

Air inlet system

  • Mounted air filter

Cooling system

  • Gear-driven circulating pump
  • Mounted belt-driven pusher fan
  • Radiator incorporating air-to-air charge cooler, (supplied loose)
  • System designed for ambients up to 50ºC (122ºF)

Electrical equipment

  • 3 level engine protection system
  • 24 volt starter motor and 24 volt 70 amp alternator with DC output
  • ECM mounted on engine with wiring looms and sensors

Flywheels and flywheel housing

  • High inertia flywheel to SAE J620 size 14
  • SAE 1 flywheel housing

Fuel system

  • Fuel cooler
  • Governing to ISO 8528-5 class G2 with isochronous capability
  • Mechanically actuated electronically controlled unit fuel injectors with full authority electronic control
  • Replaceable ‘Ecoplus' fuel filter elements with primary filter/water separator

Mountings

  • Front engine mounting bracket

Oil system

  • Full-flow replaceable ‘Ecoplus' filter
  • Oil cooler integral with filter header
  • Wet sump with filler and dipstick

Optional equipment

  • 110 volt/240 volt immersion heater
  • Additional speed sensor
  • Air filter rain hood
  • Temperature and pressure sensors for gauges
  • Tool kit
  • Twin starters/facility for second starter
 

Compact Solution

With exceptional power-to-weight ratios and compact size, our 2200 range engines are easy to transport and install and they provide excellent service access for ease of maintenance.

Engines in our ElectropaK 2200 range are delivered to you complete with radiator and air cleaner system already built on, enabling you to simply bolt the engine down, connect it up and start generating.

Reliability and efficiency

With mechanically operated unit fuel injectors with electronic control and carefully matched turbocharging, our 2200 range engines give you excellent fuel atomisation and combustion with optimum economy. The electronic control of fuel injected results in low emissions.

The engines deliver the reliable power you need. Low oil usage, low wear rates and high compression ratios mean you will get reliable, clean and rapid starting in all conditions.

Supply Assurance

MSDD Engine Standards

01
Genuine Quality & Fitment Check

We verify fitment by engine nameplate and serial number, with pre-shipment photos of original packaging.

02
Direct Export Logistics

Direct dispatch from our Chongqing hub for industrial fleets, power plants, and service centers.

03
Locked Commercial Terms

Unit price, completeness, export crating, and lead time are confirmed before invoicing.

Technical Data

Specifications

Reference parameters for engineering selection; exact arrangement details are confirmed prior to shipment. Manufacturer names and part numbers are used for identification reference only.

Additional Parameters
Model / Code2206C-E13TAG
BrandPerkins
Minimum Rating350 kVA/324 Kw
Maximum Rating450 kVA/406 Kw
50 Hz Prime Power350-400 kVA
50 Hz Standby Power400-450 kVA
60 Hz Prime Power350 kVA
60 Hz Standby Power320 kVA
Rated Speed1500/1800 rpm
Emissions StandardEU Stage II/U.S. EPA Tier 2

Engineering Advantage

Why Specify Perkins 2206C-E13TAG ElectropaK Power Generation Engine

01

Prime (PRP) and Standby (ESP) ratings are sized to your actual load profile and motor starting currents.

02

Electrical parameters are confirmed before quotation: voltage, frequency, controller model, and paralleling or ATS gear.

03

Enclosure format is matched to your site: open skid, soundproof canopy, or containerized package with climate protection.

04

Site altitude, ambient temperature derating, and acoustic limits are engineered into the configuration.

05

Lead time, export crating, and international shipping terms (FOB, CIF, DAP) are fixed prior to order confirmation.

Applications

Typical Applications

Designed for reliable prime and standby power across industrial facilities and critical infrastructure. Enclosure and switchgear are configured to your site.

Logistics & Packaging

Delivery Terms

Quantity, export packaging, gross weight, and dispatch lead time are confirmed in your formal quotation.

Packaging
Export-grade protective packaging
Unit Weight
Confirmed per configuration
Minimum Order
1 unit / per enquiry
Lead Time
Confirmed prior to order

Before You Order

Frequently Asked Questions

What technical details are required for sizing and quotation?

Please specify your required power output (kW/kVA), operating duty (Prime or Standby), ambient conditions (altitude and temperature), voltage/frequency, and destination country.

Can the configuration and scope of supply be customized?

Yes. Cooling packages, flywheel housings, control panels, canopies, and ATS switchgear are confirmed to match your application prior to quotation.

Request a Quotation

Submit Your Enquiry

Request Technical & Commercial Quote — share your requirements below and our engineers will verify fitment and stock availability.

By submitting this form, you agree to our Privacy Policy and Terms of Service. Your technical data and nameplate photos are used strictly for quotation and fitment verification.